Welcome![Sign In][Sign Up]
Location:
Search - white noise removal in matlab

Search list

[Otherxiaobo

Description: 局部放电试验所采集的信号中往往混有白噪声、周期干扰信号去除。此处采用常用db系列小波中的db6小波进行9尺度的多分辨分解后,根据白噪声能量特性,估算各尺度的阈值大小,采用硬值进行处理,后进行重构。-Partial discharge test of the signal collected is often mixed with white noise, periodic interference signal removal. Here the use of commonly used wavelet db Series DB6 wavelet carried out in the 9-scale multiresolution decomposition, based on the energy characteristics of white noise to estimate the scale threshold size, the use of hard-value deal, after the remodeling.
Platform: | Size: 33792 | Author: rex | Hits:

[Special Effectsdsp

Description: 仿真信号,添加白噪声,再用小波去除。斑竹看看,有什么问题没^_^我信号处理不行 lO*/qUo7 这个程序也在MIT提供的信号上进行了验证。-Simulation signal, add the white noise, and then wavelet removal. Chiloscyllium see what the problem did not ^ _ ^ I will not do signal processing lO*/q Uo7 This process also signals provided by the MIT verified.
Platform: | Size: 784384 | Author: 宇航 | Hits:

[matlabOFDM

Description: OFDM下行的仿真1、产生要传输随机数; 2、进行调制; 3、串并转换; 4、进行IFFT操作(代码中有用到共轭对称向量的IFFT为实数进行简化计算); 5、增加循环前缀; 6、并串转换; 7、输出前滤波; 8、增加信道噪声(加性高斯白噪声); 9、接收端串并转换; 10、去除循环前缀; 11、进行FFT变换; 12、信号解调; 13、误比特率计算; -OFDM downlink simulation 1, have to be transmitted random number 2, the modulation 3 series and transforms 4, the IFFT operation (code useful to conjugate symmetric vector of the IFFT of real numbers to simplify calculations) 5, the increase in circulating prefix 6, and string conversion 7, the output before the filter 8, increased channel noise (additive white Gaussian noise) 9, the receiver string and conversion 10, removal of cyclic prefix 11, the FFT transform 12 , the signal demodulation 13, bit error rate
Platform: | Size: 112640 | Author: 刘洋 | Hits:

[File FormatECE082

Description: Abstract— with the latest advancements in electronics, several techniques are used for removal of unwanted entities from signals especially that are implied in the most sophisticated applications. The removal of power line interference from most sensitive medical monitoring equipments can also be removed by implementing various useful techniques. The power line interference (50/60 Hz) is the main source of noise in most of bio-electric signals. The report presents the removal of power line interference, baseline wandering and additive white Gaussian noise (AWGN) from ECG signal using the different types of filtering technique. The project is based on digital signal processing (DSP) techniques with MATLAB package, the IIR Notch filter can be used for removal of power line interference, Median can be used for Baseline wandering noise and Discrete Wavelet Transform can be used for removal of AWGN.
Platform: | Size: 654336 | Author: muthupandy | Hits:

CodeBus www.codebus.net